Data Centers – A Global Perspective
- Wasted energy burdens the environment and increases operational expenses
- Carbon Footprint in IT Computing
- Only 3% of the energy entering a data center is used for net computing creating opportunities for effiency improvements (Source: IBM, 2009)
- Carbon Footprint in IT Computing
- Two complementary Eaton-proprietary technologies to maximize UPS performance & efficiency
- Variable Module Management System (VMMS)
- Maximized efficiency in double conversion mode
- Both in single- and multi-UPS systems applications
- Maximized efficiency in double conversion mode
- Energy Saver Systems (ESS)
- The ultimate savings: 99% efficiency
- Automatic fast transfer to double conversion mode when needed (in less than 2 ms)
- Variable Module Management System (VMMS)
Energy Advantage Architecture
Higher System Efficiency
No Compromise On Reliability
Variable Module Management System (VMMS)
The Challenge For UPS’s |
||
FACTS
CHALLENGE
|
The Solution:
|
The Solution: Eaton VMMS
- How to maximize efficiency with lighter loads in double conversion mode
- Especially in multi-UPS and redundant system configurations
- Solution #1 (+)
- Concentrate load on certain UPS’s to maximize UPS load level and overall system efficiency
- Some energy savings
- Limited to multiple-UPS systems (with several UPS in parallel)
- Still not optimal
- Some energy savings
- Concentrate load on certain UPS’s to maximize UPS load level and overall system efficiency
- Solution #2 (+++)
- Eaton 9395 and its Variable Module Management System
- Automatically optimize efficiency at UPM level
- Concentrate the load on certain UPM’s to maximize overall system efficiency
- Only possible thanks to modularity of Eaton 9395 UPS
- Not limited to multiple-UPS systems
- Achieve even higher optimization thanks to UPM’s modularity
- Automatically optimize efficiency at UPM level
- Eaton 9395 and its Variable Module Management System
VMMS Principle
- Example With Same Load Applied To Different Multi-UPS Configurations
- VMMS maximizes % load of each UPM
- Optimizing overall system efficiency
Energy Saver System (ESS)
Efficient 99% efficiency across entire operating range |
|
|
Intelligent Detects incoming power quality and engages modules as needed in < 2ms |
||
Reliable Proven Eaton technology ensures reliability and continuous load availability |
||
Energy Saver System (ESS) allows the UPS user to achieve the ultimate power efficiency without compromising the protection of the supported equipment.
Energy Saver System saves even more at lower loadings
Maximum Efficiency Tracking
- ESS Efficiency - 99%across the complete operating range
- 85% reduction in lossescompared to legacy transformer-based UPS
- Continuous power tracking and proprietary DSP algorithms combined with transformer free design topology ensures critical loads are always protected